Salta ai contenuti
IT
Apri l’app

For AI assistants: this page as plain markdown is at https://docs.voicelogica.ai/raw/telephony/carriers.md, and https://docs.voicelogica.ai/llms.txt lists the docs by topic, one file each, small enough to read whole. Read those rather than this HTML page.

Carrier settings

5 min di lettura
Copia come Markdown
Visualizza come MarkdownApri il file .md.md

Questi contenuti non sono ancora disponibili nella tua lingua.

Settings for the carriers our customers connect most often, taken from trunks that work in production. For the steps to add a trunk, see Your own carrier. For an office phone system (Panasonic, Grandstream, Yeastar, 3CX, FreePBX, Issabel, Alcatel, Avaya), see Connect your PBX.

In Telephony → Add Trunk, pick the carrier: the app fills in the host, port and transport below. You add the username, password and numbers.

MyVoIP SIP trunk

FieldValue
Hostsip.yuboto-telephony.gr
Port / transport5060, UDP
Registrationon, expiry 300
Username / passwordfrom MyVoIP → Devices

Some accounts get their own endpoint instead of the shared host. MyVoIP → Devices shows it.

Yuboto cloud PBX (vPBX) extension

When the agent should be an extension of a Yuboto cloud PBX, connect it as an extension of that PBX:

FieldValue
Hostyour PBX’s address, <name>.vpbx2.yuboto.com
Port / transport5060, UDP. Change them only if your PBX shows other values for that extension
Username / passwordthe extension’s

If the trunk gets no reply, check the port and transport your PBX shows for the extension: some use another port (up to 5086) or TCP.

FieldValue
Hostvoips.modulus.gr
Port / transport5060, UDP
Registrationon, expiry 300
Usernamethe Auth ID Modulus gives you, not the SIP username
  • Add every number to the trunk. Modulus sends the calls of all its customers from the same address, so we route each call by the number dialled. A call to a number that is not on any trunk is rejected rather than risk reaching another company.
FieldValue
Hostsip.supervoice.eu
Port / transport5061, TLS
Registrationon, expiry 300

If Supervoice gives you an outbound proxy, add it under Advanced on the trunk.

FieldValue
Hostsip.intertelecom.gr, or the address Inter Telecom gives you for your account
Port / transport5060, UDP
Registrationon, expiry 300

Confirm the exact host with Inter Telecom (+30 2170007000); some accounts get their own.

FieldValue
Hostsip.telnyx.com (sip.telnyx.eu for the EU region)
Port / transport5060, UDP
Registrationon
Usernamethe SIP Connection’s Auth ID

Telnyx keeps one registration per credentials-based SIP Connection. If the same credentials are also on a softphone, desk phone or another platform, the trunk keeps dropping with 401. Details in Your own carrier → Telnyx.

FieldValue
Hostyour Elastic SIP Trunk’s Termination SIP URI (<name>.pstn.twilio.com)
Port / transport5060, UDP
Authenticationby IP, both directions. No registration

In Twilio, add the Voice Logica IP addresses to the trunk’s IP Access Control List (Support gives you the current list), and point its Origination at your company’s SIP address (Telephony → Call settings).

FieldValue
Hostphone.plivo.com
Port / transport5060, UDP
Incoming callsby IP: add Plivo’s inbound IPs for your region under Advanced → Authentication
  • Business SIP trunk: Cosmote and Vodafone authenticate by IP. Ask your account manager for their signalling IPs and add them under Advanced → Authentication.
  • A landline on the internet router: see Cosmote, Vodafone and Nova. Vodafone needs host 62.38.86.150, expiry 3600 (300 is rejected) and the edge device, because it accepts registrations only from inside its network.
Why do my trunk's SIP logs show no reply from the carrier?

The host, port or transport is wrong; for a Yuboto vPBX extension, check the port and transport the PBX shows for it (5060, UDP unless it shows otherwise). Or the carrier accepts registrations only from inside its own network (Cosmote, Vodafone): in that case use the edge device.

Why does my carrier answer 401 or 403 when my SIP trunk registers?

If you get 401 again and again from the start, the username or password is wrong; for Modulus and Telnyx the username is the Auth ID. If the trunk registered earlier and now gets 401, the same account is also registered somewhere else: see Registration works, then keeps getting rejected.

Why do some calls from my Modulus trunk never reach the agent?

The dialled number is not on the trunk. Calls from Modulus are matched by number, so a number missing from the trunk is rejected. Add it under the trunk’s numbers.

Why did I get a Registration paused email about my SIP trunk?

The carrier rejected the trunk’s registration several times, so we paused it and keep retrying on our own (after 5 minutes, then longer) to keep the carrier from blocking the account. The email shows the likely cause. A successful registration recovers the trunk without any action from you.