Edge device
Esta página aún no está disponible en tu idioma.
An edge device is a small connector you install inside the customer’s network. It lets Voice Logica reach a phone system (PBX) that has no public address - an on-premise PBX at 192.168.x.x, 10.x.x.x or 172.16-31.x.x.
It only makes outbound connections. Nobody opens a port, forwards anything, or gives the PBX a public IP.
Do you need one
Section titled “Do you need one”| The PBX or carrier is… | What to use |
|---|---|
| On the office LAN, private IP only | Edge device (this page), then a Local IP PBX trunk |
| Reachable from the internet (public IP or hostname) | Your own carrier - Public IP PBX |
| A SIP carrier (Yuboto, Telnyx, Twilio…) | Your own carrier - VOIP provider |
| Registers to us (the PBX dials out) | Your own carrier - Incoming PBX |
If you type a private address into a Public IP PBX trunk, the drawer blocks it and offers switch to Local IP PBX. That is the signal you need a device.
How it works
Section titled “How it works”- The device keeps a control connection to
calls.voicelogica.aiover TCP 443 (secure WebSocket). - It brings up a WireGuard tunnel to Voice Logica over UDP 51820. SIP and call audio travel inside that tunnel.
- On the LAN side it talks to the PBX like any other SIP phone or trunk.
Both connections start from inside the network. The device cannot be reached from the internet, cannot run arbitrary commands, and cannot reach the rest of your network.
Network requirements
Section titled “Network requirements”Send this list to whoever runs the site firewall before install day.
- An always-on machine on the same network as the PBX: a Windows PC, a Linux box or Raspberry Pi, or a virtual machine. Not a laptop that sleeps or leaves the office.
- Outbound TCP 443 to
calls.voicelogica.ai. The name must resolve - DNS filtering that blocks our domain stops enrollment. - Outbound UDP 51820 to
calls.voicelogica.ai. Without it the device shows online, and calls have no audio. - All UDP both ways between the device and the PBX. A rule for port 5060 alone is not enough - audio uses changing ports.
- No inbound ports, no port forwarding, no public IP.
Full network sheet for IT: network requirements.
Install the device
Section titled “Install the device”You can start from two places. Both produce the same device:
- Telephony - Trunks - + Add Trunk - Local IP PBX. The drawer shows Download the connector with Windows, Linux and VM image, then waits for the device. Use this when you are connecting a PBX right now.
- PBX Edge Devices (
app.voicelogica.ai/phones/edge-devices) - Add Edge Device. Use this to prepare a device ahead of time, or to Email the steps to the customer when someone else is on site.
In Add Edge Device, give it a Site label (the office name, for example “HQ Office”), pick the Platform, then choose I’ll set it up now or Email the steps to the customer. The main button changes to match.
- Pick Windows and click Download installer. The
.exeis built for your company - the token is inside, nothing to type. - Copy it to the always-on Windows PC next to the PBX. Run it and accept the prompts.
- It installs WireGuard and the connector as a service and connects by itself. It starts again after a reboot.
The download link is valid for 4 hours. After that, download a fresh one (Redownload Windows in the trunk drawer).
If antivirus or a browser policy blocks the .exe, run the PowerShell one-liner instead in an Administrator PowerShell:
$env:EDGE_TOKEN='<token>'; irm https://calls.voicelogica.ai/install.ps1 | iexClaude or ChatGPT hands you this line with the token already filled in - see Or let Claude do it.
-
Pick Linux / Raspberry Pi and click Get install command.
-
Copy the line and run it on the Linux machine:
Terminal window curl -fsSL https://calls.voicelogica.ai/install.sh | sudo bash -s -- --token <token> -
It needs
curlandsudo. It uses Docker and installs it if it is missing.
At the end the script runs a short preflight - DNS, TCP 443 and the local firewall - and prints a block to send to IT if anything fails. Read it before you leave the machine.
The token in the command is valid for 72 hours.
- Pick Virtual machine and click Download appliance.
- The appliance page has the image for VirtualBox, VMware or Proxmox and the steps to import it.
- Give the VM a network adapter bridged onto the PBX network, not NAT, so it gets an address on the same LAN.
- Start the VM. Within a minute its console screen shows Claim code followed by a code like
7K2M-9QXR. - On PBX Edge Devices, click Add Edge Device, pick Virtual machine, enter the code under Claim code and click Claim device. Or give the code to Claude or ChatGPT: “Claim my edge device, the code is 7K2M-9QXR.”
The VM downloads without a company inside it, so the code is how it joins yours. It works for 24 hours after the VM first starts. Once the device is claimed, the code disappears from the screen.
Wait until it is online
Section titled “Wait until it is online”The token ties the device to your company, so it is approved automatically. A virtual machine is approved when you claim it with its code. Watch it on PBX Edge Devices (the list refreshes on its own) or in the trunk drawer:
In the trunk drawer the pill changes from Not connected to Live, and Next steps appears. Refresh devices checks now.
Connect the PBX
Section titled “Connect the PBX”-
Telephony - Trunks - + Add Trunk - Local IP PBX
Name the trunk after the site. If the device is already Live, the form unlocks right away.
-
Pick the PBX
Under Suggested PBXs on this LAN, click Find PBXs. The device scans its subnets for SIP hosts. Click a suggestion, or type the PBX’s LAN IP yourself.
-
Set the SIP port if it is not 5060
Advanced - Port. Some PBXs listen elsewhere - Alcatel OXO commonly uses 5059. Ask the PBX admin if unsure.
-
Test now
Sends SIP OPTIONS to the PBX through the device. Any answer - including 401/407 (wants credentials) - means SIP is flowing. No SIP response means wrong IP or port, or something between the device and the PBX drops SIP.
-
Credentials
The extension (or SIP trunk account) the PBX created for Voice Logica: Username, Password, and Login (Authorization ID) if the PBX uses a separate one.
-
Destination, then Create Trunk
Point unrouted calls at your AI agent. Create Trunk. Registration should show online within a minute.
-
Send calls to the agent and dial in
Route a number or a PBX queue / extension to the new trunk on the PBX side, connect it to the agent under Channels - Telephony, and call it from a real phone. Check Calls. See Your own carrier for numbers and default destination.
To change the PBX address on an existing device later, use the slider icon (Configure PBX settings) on its row in PBX Edge Devices - PBX IP address and SIP port, then Save. Pushing new settings restarts the device’s SIP relay, so do it outside a live call.
Or let Claude do it
Section titled “Or let Claude do it”If you have connected Claude or ChatGPT to Voice Logica, say “connect my PBX”. The assistant gives you the Windows download link (or the Linux command) with the token inside, watches the device come online, asks for the PBX IP, SIP port and extension login, and creates the trunk through the device. Walkthrough: Connect your PBX from Claude.
Troubleshooting
Section titled “Troubleshooting”The device is online but calls have no audio
The tunnel is down. The site firewall must allow outbound UDP 51820 to calls.voicelogica.ai. The trunk drawer says Connected, but the tunnel is down (UDP 51820); Claude reports tunnelUp: false.
If the tunnel is up and audio is still silent both ways:
- The firewall between the device and the PBX passes all UDP, not only 5060.
- On Linux, a default-deny host firewall drops audio. Run
ufw allow in on wg0on the device.
The device never comes online
- The installer finished and the machine is on (not asleep).
- Outbound TCP 443 to
calls.voicelogica.aiis allowed. - The name resolves - DNS / web filtering often blocks new domains. Allowlist
calls.voicelogica.aiandvoicelogica.ai. - The Windows link (4 hours) or install token (72 hours) had not expired. If in doubt, generate a new one.
Test now says No SIP response
The IP or port is wrong, or the PBX ignores the device. Confirm the PBX’s SIP port - it is not always 5060 (Alcatel OXO: 5059) - and set it under Advanced - Port. A 403 Forbidden means SIP arrives but the PBX rejects this source: allow the device’s LAN address on the PBX’s SIP / trunk settings.
Claude says the PBX is not reachable, but the test works
PBX reachable is a ping from the device. Many networks and PBXs block ping while SIP works fine. Trust Test now and the trunk’s registration, not the ping.
We have two PBXs on different networks
One device serves one PBX target at a time. Install a second device next to the second PBX, then create a second Local IP PBX trunk on it.
The trunk is registered but callers still reach nothing
The PBX is not sending those calls to the trunk, or the number is not on this agent. Check the PBX routing, then Your own carrier - default destination and Channels - Telephony.